Main Parameters of Frequency Converter
Types | Minimum Value | Rated Value | Maximum Value | Notes |
Input Voltage | 323VAC | 380VAC | 484 VAC | |
Input Current | 70A | Constant torque | ||
80A | Variable torque | |||
Input Frequency | 47Hz | 63Hz | ||
Output Voltage | 0 | Input voltage | ||
Output Current | 60A | Constant torque | ||
75A | Variable torque | |||
Output Frequency | 0 | 400Hz | ||
Output Power | 30KW | Constant torque | ||
37KW | Variable torque |
Control Power Electrical Parameters
Types | Minimum Value | Rated Value | Maximum Value | Notes |
Input Voltage | 400VDC | 720 VDC | ||
Input Current | 15A | Full load | ||
Start Time | 1S | |||
Output Voltage | 400 VDC | 720 VDC | ||
Output Current | 20A | |||
Efficiency | 96% | Full load |
1. Energy Saving Advantage
Stores excess energy, achieving a 40% - 50% electricity saving rate, reducing energy consumption.
2. Intelligent Control Feature
Equipped with a frequency converter, adjusts the speed according to the load, enhancing equipment efficiency.
3. Stable Operation Guarantee
Capacitor Management System (CMS) manages the capacitor, multiple protection functions ensure the safe operation of the system.
Oil Field Field
In the pumping unit system, it stores the excess energy when the donkey head goes down and releases the energy when it goes up, achieving energy conservation and avoiding "reverse power generation". At the same time, it can adjust the flushing frequency according to the actual situation of the oil well, improve the efficiency of the mechanical production system, realize the soft start and stop of the motor, reduce the impact on the power supply and distribution system, reduce the line loss, and optimize the capacity configuration of the network. The energy-saving rate can reach 40% - 50%, and the power factor can reach more than 99%.
Elevator Field
Used for elevator energy-saving, it stores the energy of the elevator car going down through energy-type supercapacitors and uses it when going up. The equipped frequency converter can adjust the motor speed according to the load, saving energy and avoiding motor overload, effectively improving the equipment efficiency.
Power System Field
Applied to frequency regulation in wind power, thermal power, and other fields to ensure the stable operation of the power system. For example, in wind power, it helps smooth the output power fluctuation, and in thermal power, it assists in adjusting the output power of the unit to better adapt to the load change of the power grid and maintain the stability of the grid frequency.
Get in Touch with Tsingyan for Energy Storage Solutions
at Anytime!
Unlock the future of advanced sensor technology with Tsingyan!
Our cutting-edge dry electrodes are designed for superior performance.